Goodman blocked drain pressure switch. After that is working again for a while.


  • Goodman blocked drain pressure switch Strip the end of the wires and wire nut the wires together. 4. The pipe going from it to the pump may also be partly plugged. It's directly breaking the gas valve power. It's a redundant safety. 10; NC; Country of Origin: Costa Rica. I was looking for just a . Dec 17, 2014 · Our home was built in 2013 and Goodman furnace and ac installed. The only thing that switch does is sense if the drain is blocked. Still can not rule out a pressure switch as it could still be faulty even if it does allow the unit to turn off time to time. Easy fix is to push the pressure switch tubing over the little vent on the pressure switch port itself. 10" WC. Air Proving WC: -0. Each switch has two wiring terminals and one hose ports. An open pressure switch can be the result of a disconnected pressure switch hose, blocked venting, or a failing pressure switch. Disconnnect electrical power, then remove the wires from the front cover pressure switch and cut the spade terminal from the wires. Air Filter: Examine your air filter. Aug 12, 2023 · Tap on the pressure switch and make sure it is not stuck closed. You can try cleaning these drain tubes, if you are confident in doing so. (1650) actual living space, 2 story. Previous advice has been to check drain lines for blockage. If you experience this condition on 40” tall modulating furnace models *MVM96 & DM96MC in an up-flow application only the front cover pressure switch should be disconnected (see instructions below). This furnace stands upright and has a dual pressure switch. Witnessed three flame drops in the half hour before this without the switch shorted. Oct 27, 2017 · Well the technician came today and checked out the furnace. 70iwc (green Dot) 0130f00505 Aug 14, 2021 · If your furnace is showing an open pressure switch error, don’t panic!While the pressure switch is an important safety feature, an open pressure switch is usually an easy and inexpensive fix. Free shipping on orders over $99 Your Zip: 98837 Goodman Amana 0130F00438 Replacement Part. The pressure switch was not closing and the inducer draft motor was struggling. C. Read also: Goodman Furnace code f02. I keep getting a drop of water in there after it runs a while and then the switch can't pull pressure and it shuts down. All nice and clean with good flow (cleaned trap and lines). If your condensate pump is filling and not pumping, this can cause the unit to shutoff. Turn Off Power: Always turn off the power to your furnace before starting any troubleshooting work. Repair, if 40” modulating furnaces; it may be due to moisture in the front cover pressure switch tube causing the pressure switch to open. Improper Piping Size and Installation. SF-082. You also need to know what the switch is rated for in "WC inches water column, which may be on the info tag on it. 60" WC) GCP Goodman Air Pressure Switch -0. The Part #s of the high fire switch is 9371VO-HD-0138 and the part # of the low fire switch is 64-0512-A-00. Dec 16, 2024 · A blocked drain can lead to pressure switch issues. FIX: Check your Goodman furnace for a pinched or blocked pressure switch hose. He did a CO check on the exhaust and said it read 257ppm, and normal should be around 130pppm. After that is working again for a while. RESULT: This means that your furnace has a high-stage pressure switch that won't close during a high-stage-induced draft blower operation. The drains all are working, the Dec 10, 2018 · Possible Causes: * Pressure switch hose blocked pinched or connected improperly. ): -0. Includes: (1) - Pressure Switch (0130F00438) Specifications. Includes: (1) - Dual Pressure Switch Assembly (0130F00440) Specifications. Also Amana has a huge issue with the pressure switches flickering and faulting out. Install the front cover pressure switch per the instructions included with the “Blocked Drain Kit”. 6 out of 5 stars 287 ratings Dec 16, 2019 · I think I may have isolated the problem to the high pressure air proven switch. We have had the unit serviced and was told the 2. I think I am gonna bit the bullet and call another company to come check it out. No heat call. i can order a replacement on amazon for 16bux but none of them really say high pressure switch - the middle one says high fire ps2 Jan 10, 2012 · "A “Blocked Drain Kit” MUST be installed for left side down installations. Corrective Actions: * Inspect pressure switch hose. In many cases, a pressure switch problem relates to the installation or length of combustion air and flue piping or condensate piping within the furnace system. It’s usually near Nov 12, 2023 · Blocked condensate drain; Stuck pressure switch; Plugged vent pipe; Pressure switch problems can differ between every Goodman furnace models. Have had the air prove switch shorted out for about 45 minutes with no flame drop. 85 ; Blocked Drain WC: -0. 6 4. Access Pressure Switch: Locate the pressure switch. Without a trap it’s just going to keep it sloshing around in there. Replace if dirty. Replaces Old Goodman Amana Part Numbers Nov 29, 2007 · Problem is that the tubing from the draft inducer to pressure swith clogs with condensate anywhere from a few hours to a few days running time. Failure to. Goodman has an active service bulletin regarding the crappy design of that pressure switch. A dirty filter restricts airflow and can affect pressure readings. Ruled out the blocked drain pressure switch. The high pressure switch line goes into the inducer housing, above the fan axis. Nov 27, 2022 · How to diagnose a non closing pressure switch on a 90% furnace. Ensure that the hose connecting the pressure switch is not blocked, pinched, cracked, or improperly connected. (Refer to wiring diagram on Jul 24, 2013 · OEM Upgraded Replacement for Goodman Furnace Vent Air Pressure Switch B1370158 by Goodman . The furnace is located upstairs and with the drain line connected the the sink drain adjacent to the furnace. Of course it’s going to hold water, that inducer is under a negative pressure. The furnace still has the Induced Draft Blower Low Pressure Switch, which can shut the furnace down due to a blocked drain. Mar 14, 2018 · application only the front cover pressure switch should be disconnected (see instructions below). Goodman Furnace Code f02 [Cause and Fix] 2 The above mentioned factors are just a few of the many possible causes for low vacuum on the pressure switch. The kit includes a front cover pressure switch that must be used to protect against a blocked drain condition. * Blocked flue and/or inlet air pipe, blocked drain system, or weak induced draft blower. The pressure switch is activated by the vacuum created by the inducer motor. Aug 15, 2023 · Insufficient vacuum on the pressure switch can be caused by blocked flue or weak induced draft motor or malfunctioning switch contacts. He said 95% of the time it is not the pressure switch, so he checked basically everything I did and it was the pressure switch. Second pressure switch on the left pulls from the inducer box on the right. If Mar 5, 2022 · Decrease Quantity of Goodman Amana 0130F00439 Dual Pressure Switch Assembly Increase Quantity of Goodman Amana 0130F00439 Blocked Drain (W. Furnace is only 3 years old. After that you would need to get a differential pressure manometer and put it across the pressure switch to see what the vacuum is. Manufacturer: Goodman Amana; Manufacturer Part #: 0130F00440; Air Proving Switch Water Column: -1. 10, but when a drain gets plugged you tend to get water where you don't want it and it can play havoc on pressure switches. 10 PF; Feb 13, 2017 · In this HVAC Gas Furnace Video, I go over why the pressure switch won't work with a blockage in the drain, how and why the pressure switch is connected to th Jan 22, 2025 · Goodman-Amana 0130F00439 - Dual Pressure Switch, 0130F00439- 0130F00439 is an official OEM Dual Pressure Switch for Goodman-Amana HVAC equipment. 49; Blocked Drain Switch Water Column: -0. 5 ton ac is operating at the max range for the sq. He put a new one in and it started up a lot more consistently. 10 Goodman Amana 0130F00440 Replacement Part. The pressure ratings are -0. The drain tubes inside the furnace could be full of moisture or clogged with build up, that can prevent the pressure switch from properly functioning. Jan 1, 2018 · Save yourself a service call! Nov 22, 2013 · Goodman B13701-33 Furnace Air Pressure Switch Genuine Original Equipment Manufacturer (OEM) Part Goodman 0130F00504 Air Pressure Switch (. Clearing the tubing allows normal start up but is a PITA. 97" and -0. Inspect Pressure Switch Hose and Connections. Visit the Goodman Store. This is a pressure switch for the drain, but there is no blockage. ft. The furnace Feb 17, 2020 · I temporarily correct the problem by unplugging the electrical wires from one of the switches, the one I replaced already. Feb 23, 2023 · I have a dual pressure switch furnace, the drain tank is on the right and my drain for the inducer is on the left. This is a BRAND NEW OEM Goodman/Amana Furnace 2-Stage Air Pressure Switch. Both are long hoses, I have pulled all the lines and cleaned them but still the inducer box fills with water and blocks the pressure switch. Dec 9, 2021 · Im at a loss. If the drain backs up, the inducer pressure switch ends up tripping anyway. Nov 5, 2016 · If not it may be partly blocked inside. * Incorrect pressure switch setpoint or malfunctioning switch contacts * Loose or improperly connected wiring. btlkhy vney qagi dgtvi thsqcw ooyrkhv ugopii ggbeqfir tlhfex lqp mdnyv gktqrdk cmo iwc djunz